Polymer Characterization Facility Instruments

Gel Permeation Chromatography

Gel Permeation Chromatography – Wyatt Triple Detector- THF

Location: D418

Gel permeation chromatography, also known as size exclusion chromatography, is an analytical method which separates analytes based on molecular size (hydrodynamic volume). Gel permeation chromatography is often used to analyse polymeric analytes and is useful for determining the average molecular weight (Mn) of a sample and the distribution of molecular weights (Dispersity/Polydispersity Index, Đ/PDI) in the sample. This instrument is equipped with a refractive index detector, multiple angle light scattering detector and viscometer for absolute molecular weight and intrinsic viscosity determination.

– Solvent: chloroform 

– Detectors: Wyatt miniDawn Tristar light scattering detector, Wyatt ViscoStar intrinsic viscosity detector, Wyatt Optilab rex refractive index detector. 

– Molecular weight range: 200 g/mol to 600,000 g/mol

Gel Permeation Chromatography – Malvern OMNISEC Triple Detector

Location: D418 Instrument Room

The Malvern OMNISEC Gel Permeation Chromatography system is used to separate macromolecules according to their size or hydrodynamic volume. This instrument is equipped with refractive index, light scattering, and absorption photodiode array detectors. GPC characterization of synthetic and natural polymers enables the determination of molecular weight (Mn, Mw, Mz), dispersity (Mw/Mn), and other parameters. The Malvern OMNISEC uses THF as the solvent, has refractive index, light scattering, and absorption photodiode array detectors, and the molecular weight range is from 200 Da to 10 MDa. 

– Solvent: tetrahydrofuran (THF)

– Detectors: integrated Malvern refractive index (RI), right-angle light scattering (RALS), low-angle light scattering (LALS), and intrinsic viscosity detectors. 

– Molecular weight range: 100 g/mol to 20,000,000 g/mol

Gel Permeation Chromatography – Malvern OMNISEC Triple Detector

Location: D418

The Malvern OMNISEC gel permeation chromatography (GPC) system is a separation instrument that separates analytes based on their hydrodynamic size. Generally used for analyzing polymers, the GPC is able to report the molecular weight average (Mn), molecular weight distribution (PDI = Mw/Mn), and chromatogram of the analytes through the use of refractive index and light scattering detectors. The Malvern OMNISEC uses tetrahydrofuran (THF) as the solvent.

Gel Permeation Chromatography – Chloroform Triple Detector

Location: D418 Instrument Room

The chloroform gel permeation chromatography (GPC) system is a separation instrument that separates analytes based on their hydrodynamic size. Generally used for analyzing polymers, the GPC is able to report the molecular weight average (Mn), molecular weight distribution (PDI = Mw/Mn), and chromatogram of the analytes through the use of refractive index and light scattering detectors. The chloroform GPC uses chloroform as the solvent, allowing for the analysis of analytes not soluble in the common GPC solvent, THF.

Differential Calorimetry

TA® DSC2500

Location: A242

The Schafer group has a TA® DSC2500 located in lab A242 in the chemistry building. The instrument is used for differential calorimetry, wherein thermal transitions of polymers can be detected. Tests may include determination of specific heat capacities of polymer materials, as well as temperatures of fusion, crystallization, and glass transition events. The instrument is equipped with a 54-position autosampler and a TA® Refrigerated Cooling System 90. Its temperature range is between -90 and 725 °C. There is also a Tzero press and pans used for sample preparation.

Dynamic Light Scattering – DynaPro Titan

The DynaPro Titan is a dynamic light scattering instrument that can analyze a wide range of samples. The instrument can measure sizes ranging from 1-1000 nm and can study samples at temperatures from -4°C to 80°C using the integrated temperature controller. For protein solutions, the optimal concentration is 1-2 mg/mL. The instrument can also determine the translational diffusion coefficient and hydrodynamic radius of the sample to calculate the weight-average molar mass.

Film Thickness Measurements – Filmetrics F20

Location: D418 Instrument Room

The Filmetrics F20 is used for film thickness measurements. Reflectance spectra can be collected at wavelengths between 390-1050 nm and enable the determination of film thicknesses as well as refractive indices. Collection of reflectance spectra as well as model fitting can be completed in seconds. The F20 can measure films with thicknesses on the order of 15 nm- 70 μm in addition to differentiating between layers present in the film.

Fluorescence Spectroscopy – Edinburgh FS5

Location: D418 Instrument Room

The Edinburgh FS5 is a spectrofluorometer designed to measure the emission of light from samples in neat solid, film, or solution states in the range of 200 – 900 nm. With a cryostat, it can be used to obtain photophysical properties in both air and vacuum or inert atmosphere at various temperatures. This instrument is capable of measuring delayed and prompt fluorescence and phosphorescence lifetimes, with the duration ranging from nanoseconds to seconds, using either time-correlated single photon counting or multi-channel scaling methods. With the integrating sphere module, absolute quantum yields can also be measured. The Edinburgh FS5 has a photomultiplier R928P detector, with spectral coverage from 200 nm – 900 nm.

Potentiostat/Galvanostat – BASi Epsilon Eclipse

Location: D418 Instrument Room

The potentiostat/galvanostat is used for electrochemical characterization of films and solutions. Electrochemical characterization enables the determination of reductive and oxidative potentials in addition to semi-quantitative and quantitative analysis and compositional information of samples. The Epsilon Eclipse can perform linear sweep voltammetry, cyclic voltammetry, chronoamerperomentry/potentiometry, etc. Sweep rates of 1 mV/s to 25 V/s and pulse widths as low as 3 ms can be achieved using this instrument.

Spectrophotometry – Agilent Cary 60 UV-vis

Location: D418 Instrument Room

The Agilent Cary 60 UV-vis spectrophotometer is an instrument designed to capture the absorbance spectra from samples in solution at wavelengths from 200 – 1100 nm. It is a double-beam instrument that uses a xenon lamp along with a monochromator with a spectral bandwidth of 1.5 nm. This instrument can be used to measure the absorbance of a material, generate Beer’s Law plots to determine molar absorptivity, and monitor reaction kinetics, among other experiments.

Thin Film Preparation – WS-650-23B Spin Coater

With maximum rotational speeds of up to 12,000 RPM, the WS-650-23B is capable of spin coating a variety of polymer samples onto substrates such as glass, quartz, or silicon wafers. The closed bowl design helps to maintain uniformity and minimize particle contamination.

Atomic Force Microscopy – Asylum Cypher S

Location: D512 (inside the northwest turret of D-Wing)

The Asylum Cypher S atomic force microscope is capable of high-resolution imaging of a multitude of samples including films, polymers, nano and biological materials, etc. under ambient conditions. The Cypher instrument enables fast imaging times using a variety of imaging methods including contact and non-contact modes. The instrument enables determinations of height and dimensional profiles, Young’s modulus, hardness and other mechanical properties.